Implementation of a microplate based assay for the assessment of the oxygen radical absorbance capacity (ORAC)
Barbara Stadlmayr
Art der Arbeit
Diplomarbeit
Universität
Universität Wien
Fakultät
Fakultät für Lebenswissenschaften
Betreuer*in
Karl-Heinz Wagner
Volltext herunterladen
Volltext in Browser öffnen
Alle Rechte vorbehalten / All rights reserved
DOI
10.25365/thesis.3876
URN
urn:nbn:at:at-ubw:1-29505.92113.243363-9
Link zu u:search
(Print-Exemplar eventuell in Bibliothek verfügbar)

Abstracts

Abstract
(Deutsch)
Das erste Ziel der Diplomarbeit war die Entwicklung einer auf Mikrotiterplatten basierten Methode zur Erfassung der Oxygen-radical-absorbance-capacity (ORAC).Der zweite Ansatz umfasste die Bestimmung der antioxidativen Kapazität im Plasma von Ironmantriathleten innherhalb des FWF finanzierten Projektes "Risk- assessment of Ironman-triathlon participants". Die Verwendung des Mikroplattenlesegerätes FLUOstar Optima in Kombination mit 96-well Platten ermöglichte eine hohe Probendurchsatzrate, 100 Proben/Tag. Mit Hilfe der gewählten Methode wurde die antioxidative Aktivität im Plasma von 42 Ironmantriathleten bestimmt. Die erfaßten ORAC Werte trugen zur Aufklärung der komplexen Beziehung zwischen freien Radikalen und Antioxidantien nach intensiver physischer Belastung bei. Dafür wurden Blutproben von gut trainierten Triathleten entnommen und die Oxygen-radical-absorbance-capacity 2 Tage vor dem Ironmantriathlon, 20 Minuten, 1, 5, und 19 Tage nach dem Bewerb gemessen. Der ORAC Test liefert reproduzierbare Ergebnisse und zeigt eine gute Linearität zwischen Konzentration und Fluoreszenz. Bezieht man die ORAC Werte auf das Studienkollektiv, zeigte sich ein Anstieg der antioxidativen Kapazität unmittelbar nach dem Bewerb. Einen Tag nach dem Bewerb lagen die Werte immer noch signifikant über den Ausgangswert. Nach fünf Tagen näherten sie sich wieder dem Ausgangsniveau.Die eingesetzte Methode ist für die Erfassung der antioxidativen Kapazität im Plasma gut geeignet und ist mit der standardmäßigen Ausstattung eines Labors durchführbar. Außerdem erwies sich die Methode als kostengünstig, schnell und einfach in der Handhabung. Die vorliegende Arbeit zeigt, dass gut trainierte Athle- ten nach einem Ironmantriathlon keinen persistenten oxidativen Stress ausgesetzt sind. Dieser Effekt ist wahrscheinlich auf eine trainingsinduzierte Adaptierung des antioxidativen Systems zurückzuführen.
Abstract
(Englisch)
The first objective of the thesis was the application of a microplate based assay for the assessment of the oxygen radical absorbance capacity (ORAC). The second objective was referred to the detection and validation of the antioxidant capacity in plasma samples of well trained Ironman-triathletes, within the FWF fundend project "Risk-assessment of Ironman-triathlon participants". The use of the device FLUOstar Optima in combination with 96-well microplates allowed a high sample throughput of 100 samples a day. Within the applied method we determined the antioxidant capacity in plasma of 42 Ironman-triathletes. The measured ORAC values contributed to the elucidation of the complex relationship between free radicals and antioxidants after a single bout of ultra endurance exercise. Therefore, the blood samples of the well trained triathletes of 5 different time points (prerace, 20minutes postrace, 1d, 5d, 19d postrace) were analysed. The ORAC assay provides a good linear relationship between concentration and fluorescence. Concerning the study collective the ORAC values increased significantly immediately postrace and remained higher until 1d postrace. After five days, ORAC values returned to prerace concentrations. The applied method offers a good index of antioxidant capacity in biological fluids within the technological equipment of every laboratory. Moreover it is inexpensive, reagents are simple to prepare and the procedure is fast. The data of the current work demonstrates that there is no persistent oxidative stress in well trained athletes after an Ironman triathlon, probably due to training and exercise induced adaptions of the antioxidant defense system.

Schlagwörter

Schlagwörter
(Englisch)
ORAC oxidative stress antioxidant capacity radicals pyhsical exercise antioxidant capacity assays ultra-endurance exercise antioxidant defense system Ironman-triathletes
Schlagwörter
(Deutsch)
antioxidative Kapazität Ironmantriathleten freie Radikale Antioxidantien ORAC-Test oxidativer Stress antioxidative System
Autor*innen
Barbara Stadlmayr
Haupttitel (Englisch)
Implementation of a microplate based assay for the assessment of the oxygen radical absorbance capacity (ORAC)
Paralleltitel (Deutsch)
Entwicklung einer Mikrotiterplatten basierten Methode zur Bestimmung der Oxygen radical absorbance capacity (ORAC)
Publikationsjahr
2009
Umfangsangabe
X, 60 S. : graph. Darst.
Sprache
Englisch
Beurteiler*in
Karl-Heinz Wagner
Klassifikationen
30 Naturwissenschaften allgemein > 30.03 Methoden und Techniken in den Naturwissenschaften ,
35 Chemie > 35.71 Biochemische Methoden ,
35 Chemie > 35.79 Biochemie: Sonstiges ,
44 Medizin > 44.14 Gesundheitsvorsorge ,
76 Sport > 76.24 Sport für besondere Zielgruppen
AC Nummer
AC07583622
Utheses ID
3415
Studienkennzahl
UA | 474 | | |
Universität Wien, Universitätsbibliothek, 1010 Wien, Universitätsring 1